| Specifications | 500VA | 1 KVA | 2 KVA | 3 KVA | 5 KVA | 10 KVA | |
|---|---|---|---|---|---|---|---|
| capacity (KVA) | 0.5 | 1 | 2 | 3 | 5 | 10 | |
| Maximum load current (A) | high-grade | 2.08 | 4.16 | 8.33 | 12.5 | 20.83 | 41.66 |
| low-grade | 4.16 | 8.33 | 16.66 | 25 | 41.66 | 83.33 | |
| Specifications | 15 KVA | 20KVA | 30KVA | 45 KVA | 60KVA | 100 KVA | |
|---|---|---|---|---|---|---|---|
| capacity (KVA) | 15 | 20 | 30 | 45 | 60 | 100 | |
| Maximum load current (A) | high-grade | 62.5 | 83.3 | 125.0 | 187.5 | 250.0 | 416.6 |
| low-grade | 125.0 | 166.7 | 250.0 | 375.0 | 500.0 | 833.3 | |
| Specifications | Single in and single out program-controlled variable frequency conversion power supply |
|---|---|
| AC Input | Below 10KVA: Single-phase 110VAC or 220VAC ± 10%; 50Hz ± 50Hz Above 10KVA: three-phase 380VAC ± 10%; Three phase four wire+ground wire; 50Hz ± 50Hz |
| AC Output | Low grade 1.0~150.0VAC, high grade 150.1~300.0VAC |
| output frequency | Below 20KVA: 45-400Hz, adjustable Above 20KVA: 45-65Hz, adjustable |
| Frequency Adjustment | Adjust the stride of 0.1Hz, shortcut keys: 50Hz, 60Hz |
| frequency stability | ≤0.1% |
| voltage stability | ≤1% |
| degree of distortion | ≤2%(THD) |
| Source voltage effect | ≤1% |
| Load effect | ≤1% |
| Efficiency | ≥90% |
| Frequency display | 0.1% readings, with a resolution of 0.1Hz |
| Voltage display | ± (0.5% reading + 0.5% range), resolution of 0.1V |
| Current Display | ± (0.5% reading + 0.5% range), resolution 0.001A/0.1A |
| Power display | ± (0.5% reading + 0.5% range), resolution 0.01W/0.1KW |
| The power factor display | ± 0.1 with a resolution of 0.01 |
| Preset function | Output voltage, output frequency, output current upper limit / communication address |
| Shortcuts function | Common voltage, frequency conversion, M1 M2 M3 three groups of shortcut group storage |
| Alarm function | Send an alarm (sound and light) signal to display the fault code; |
| overload capacity | 1.0 Ie / 1.1 Ie |
| overheat protection | Power device temperature is greater than 85°C ± 5°C |
| External communication interface (optional) | Standard with MODBUS RTU communication protocol, upper computer software. RS-232C (standard) / RS485 (optional). |
| Case protection grade | IP20 |
| Case structure | Cabinet-type (with casters) |
| work environment | Temperature: -10°C ~ 40°C Humidity: 10%~90% (25°C without condensation), with an altitude of 2km |
| Power specifications | Overload protection conditions |
|---|---|
| (0.5-5) KVA | Continuous operating condition: P output 1.0P rating / I output 1.0I rating |
| Off output within 15 seconds: 1.0P rated | |
| Turn-off output within 5 seconds: 1.2P rated | |
| Immediately turn off output: 2.0I rated | |
| Above 10 KVA | Continuous operating condition: P output 1.0P rating / I output 1.0I rating |
| Off output within 15 seconds: 1.0P rated | |
| Off output within 5 seconds: 10KVA~20KVA:1.1P rated 30KVA and above: 1.1P rated |
|
| Immediately off output: 1.5I rated |