1 / 5
| Model | MY-L3003F | MY-L3005F | MY-L6003F | MY-L6005F | MY-L15001F |
|---|---|---|---|---|---|
| Voltage | 0 ~ 30V | 0 ~ 30V | 0 ~ 60V | 0 ~ 60V | 0 ~ 150V |
| Current | 0 ~ 3A | 0 ~ 5A | 0 ~ 3A | 0 ~ 5A | 0 ~ 1A |
| Line Regulation | |||||
| Voltage | ≤0.1%+3mV | ≤0.1%+3mV | ≤0.1%+3mV | ≤0.1%+3mV | ≤0.1%+3mV |
| Current | ≤0.01%+3mA | ≤0.01%+3mA | ≤0.01%+3mA | ≤0.01%+3mA | ≤0.01%+3mA |
| Load Regulation | |||||
| Voltage | ≤0.1%+2mV | ≤0.1%+2mV | ≤0.1%+2mV | ≤0.1%+2mV | ≤0.1%+2mV |
| Current | ≤0.01%+5mA | ≤0.01%+10mA | ≤0.01%+5mA | ≤0.01%+10mA | ≤0.01%+5mA |
| Ripple & Noise | |||||
| Voltage | ≤1mVrms | ≤2mVrms | ≤2mVrms | ≤2mVrms | ≤1mVrms |
| Current | ≤3mArms | ≤3mArms | ≤3mArms | ≤3mArms | ≤3mArms |
| Display | |||||
| Voltage | 10mV | ||||
| Current | 1mA | ||||
| Readback value resolution | |||||
| Voltage | 10mV | ||||
| Current | 1mA | ||||
| Operating environment | |||||
| Usage | for indoor use | ||||
| Elevation | ≤2000m | ||||
| Temperature | -10℃ ~ 40℃ | ||||
| Humidity | ≤80% | ||||
| Storage environment | |||||
| Temperature | -20℃ ~ 80℃ | ||||
| Humidity | ≤80% | ||||
| Power input | AC 220V ± 10%, 50/60Hz | ||||
| Size | |||||
| Size | 280(D) × 130(W) × 165(H) mm | ||||
| Package size | 355(D) × 178(W) × 210(H) mm | ||||